THE NON-STRUCTURAL COMPOSITION OF THE COTTON-MIXED WASTE BEING FED TO THE REGENERATOR

Authors

  • A.Dj.Gafurov
  • J.Sh.Mardonov
  • T.O.Tuychiev

Abstract

Annotation: The amount of cotton waste mixed with impurities from the impurities augers of the UXK cleaning flow is 66.33%, of which active impurities are 7.9% and passive impurities are 58.43%. After processing this cotton through the existing and recommended RX regenerators, the impurities in the cotton content are 11.49; 4.84% and the cleaning efficiency is 82.67; 92.7%.

References

REFERENCES:

Tuychiev T. et al. Investigate the movement of cotton in the supplier //AIP Conference Proceedings. – AIP Publishing, 2022. – Т. 2650. – №. 1.

Tuуchiеv T., Gаfurоv А., Jumаmurаtоvа V. Еxpеrimеntаl rеsults оf thе imprоvеd cоttоn rеgеnеrаtоr undеr prоductiоn cоnditiоns //Е3S Wеb оf Cоnfеrеncеs. – ЕDP Sciеncеs, 2024. – T. 497. – R 03039.

Tuychiev T. et al. Influence of the Direction of Movement of Cotton to Pile Drums on the Cleaning Efficiency //International Scientific Conference on Agricultural Machinery Industry “Interagromash"”. – Cham : Springer International Publishing, 2022. – С. 2084-2091.

Ruzmetov R., Mardonov B., Tuychiev T. Simulation of the process of cotton drying under the influence of a heat agent in a spiked-screw cleaner //E3S Web of Conferences. – EDP Sciences, 2024. – Т. 497. – С. 03057.

Madumarov I. et al. Experimental results of an improved supplier in the production process and transportation //Transportation Research Procedia. – 2022. – Т. 63. – С. 2998-3004.

Downloads

Published

2024-12-10