THE NON-STRUCTURAL COMPOSITION OF THE COTTON-MIXED WASTE BEING FED TO THE REGENERATOR
Abstract
Annotation: The amount of cotton waste mixed with impurities from the impurities augers of the UXK cleaning flow is 66.33%, of which active impurities are 7.9% and passive impurities are 58.43%. After processing this cotton through the existing and recommended RX regenerators, the impurities in the cotton content are 11.49; 4.84% and the cleaning efficiency is 82.67; 92.7%.
References
REFERENCES:
Tuychiev T. et al. Investigate the movement of cotton in the supplier //AIP Conference Proceedings. – AIP Publishing, 2022. – Т. 2650. – №. 1.
Tuуchiеv T., Gаfurоv А., Jumаmurаtоvа V. Еxpеrimеntаl rеsults оf thе imprоvеd cоttоn rеgеnеrаtоr undеr prоductiоn cоnditiоns //Е3S Wеb оf Cоnfеrеncеs. – ЕDP Sciеncеs, 2024. – T. 497. – R 03039.
Tuychiev T. et al. Influence of the Direction of Movement of Cotton to Pile Drums on the Cleaning Efficiency //International Scientific Conference on Agricultural Machinery Industry “Interagromash"”. – Cham : Springer International Publishing, 2022. – С. 2084-2091.
Ruzmetov R., Mardonov B., Tuychiev T. Simulation of the process of cotton drying under the influence of a heat agent in a spiked-screw cleaner //E3S Web of Conferences. – EDP Sciences, 2024. – Т. 497. – С. 03057.